LONG RANGECCDbarcodescanner usermanual MAN-460873-UM-0110-01460873
7Number as keypad data Once this function is activated, the output of the scanning comes from the numerical pad’s code. <number as normal data>
8please lock the keyboard before testing the scanner. Enable Upper Case Output characters in upper case. The results will be affected by the keyboard
9200 msec 300 msec
10 Code Type 4.1 Code Selection If “Enable” is selected for all the barcode types, then the scanner could read all types of barcode. If “Disable”
11<Enable EAN-8 / JAN-8> Disable EAN-8 / JAN-8 <Enable CODE 39> Disable CODE 39 <Enable CODE 128> Disable CODE 128 <Enable
12Enable CODE 93 <Disable CODE 93> Enable CODE 11 <Disable CODE 11> Enable China Postage <Disable China Postage> Enable MSI/P
13RSS-14 <Disable RSS-14> RSS Limited <Disable RSS Limited> RSS Expanded <Disable RSS Expanded>
144.2 Bar Code ID With this function on, a leading character will be added to the output string while scanning code; user may refer to the following
154.3 User Define Code ID User define code ID will override default value. It is possible to have more than two symbologies which have same code ID
16CODE 93 CODE 11 China Postage MSI/PLESSEY Code 2 of 6 Telepen LCD25 Reserved 5 Reserved 6 RSS-14 RSS Limited RSS Expanded
1Content Introduction... 1 1.1 General ...
174.4 UPC/EAN/JAN > Reading Type Enable UPC-A= EAN 13 add 0 before UPC-A to make it 13 digits. <Disable UPC-A = EAN 13> Enable ISBN-
18Enable GTIN format <Disable GTIN format> > Supplemental Setup <No Supplement Required> Enable 2 Digit Supplemental Enable 5 Digi
19< EAN-8 Check Digit Transmission> Disable EAN-8 Check Digit Transmission < EAN-13 Check Digit Transmission> Disable EAN-13 Check Dig
20Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit > Output Start / Stop Character <start/stop character = “*”>
21same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 sets Available) 1 1st Set Begin 2 Decimal Value
224.6 Code 128 > Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Tr
23 < Variable> The output would be the same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 sets
243 Minimum Length Complete 4.7 Interleave 25 > Check Digit Transmission <Do not Calculate Check Digit> Calculate Check Digit and Trans
25> Brazilian Banking Code Enable Brazilian Banking Code <Disable Brazilian Banking Code> > Setup Code Length 1. Scan the “Set Begin
26Minimum Length 1 Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will
2Content 4.9 Matrix 25 ...28 4.10 CODABAR/NW7 ...
27There is no limit in length for the reading output. Fix Length (2 Sets Available) 1 1st Set Begin 2 Decimal Value Appendix A 3 1st Set Complete
28 > IATA 25 Enable IATA 25 <Disable IATA 25> 4.9 Matrix 25 > Check Digit Transmission <Do not Calculate Check Digit> Calcula
291 1st Set Begin 2 Decimal Value Appendix A 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value Appendix A 3 2nd Set Complete Minimum Length 1
30<Disable Start/Stop characters> > Transmission Type of Start/Stop <A/B/C/D><Start> <A/B/C/D><Stop> A Start A
31> Setup Code Length 1. Scan the “Set Begin” Bar Code (2 Sets Available) 2. Go to Decimal Value Table in Appendix A, scan Bar Code(s) that rep
32the scanner will not output the data. 2 Decimal Value Appendix A 3 Minimum Length Complete 4.11 Code 93 > Check Digit Transmission <
333 1st Set Complete 1 2nd Set Begin 2 Decimal Value Appendix A 3 2nd Set Complete Minimum Length 1 Minimum Length Set a minimum length for cod
34Calculate Check 2 Digit and Transmit Calculate Check 2 Digit and Not Transmit > Setup Code Length 1. Scan the “Set Begin” Bar Code (2 Sets
35Minimum Length 1 Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will
36< Variable> The output would be the same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 Sets A
1 Introduction 1.1 General SG300RFM has been factory configured with a set of default parameters. All factory default settings are shown with <>
374.14 Code 2 of 6 > Check Digit Transmission Do not Calculate Check Digit <Calculate Check Digit and Transmit> Calculate Check Digit an
383 2nd Set Complete Minimum Length 1 Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, th
39> Setup Code Length 1. Scan the “Set Begin” Bar Code (2 Sets Available) 2. Go to Decimal Value Table in Appendix A, scan Bar Code(s) that rep
40the scanner will not output the data. 2 Decimal Value Appendix A 3 Minimum Length Complete 3 Minimum Length Complete 4.16 LCD 25 > Check Di
41Fix Length (2 Sets Available) 1 1st Set Begin 2 Decimal Value Appendix A 3 1st Set Complete 1 2nd Set Begin 2 Decimal Value Appendix A 3 2nd S
42RSS-14 Don’t Transmit Check Digit Transmit RSS-14 Application ID Don’t Transmit RSS-14 Application ID Transmit RSS-14 Symbology ID Don’t Transm
43Don’t Transmit RSS Limited Symbology ID 4.19 RSS Expanded > Check Digit Transmission Transmit RSS Expanded Symbology ID Don’t Transmit RSS Ex
44 PREFIX/SUFFIX 5.1 Standard Suffixes None Data are displayed continuously <CR+LF> The cursor moves to the left once data are displayed, and
45Enable Space Once data are displayed, the cursor will skip a space to get ready for the next data. Enable Tab(HT) Once data are displayed, the cur
467. Scan “End” 8. Scan “Save” Repeat Steps 1-6 to set additional set > Example Insert $ as Prefixes for Code UPC-A Start Set #1 Scan the bar c
2 This marking shown on the product or its literature, indicates that it should not be disposed with other households wastes at the end of its
47Scan “Save” bar code > Insertion Set Number Set #1 Set #2 Set #3 Set #4 Set #5 Set #6 > Code Type to be inserted UPC-A UPC-E EAN
48CODE 128 CODABAR/NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 China Postage MSI/PLESSEY Code 2 of 6 Telepen Resvered 5 LCD
49RSS Limited RSS Expanded All Codes None > Character Position to be inserted
50 Complete > Character to be inserted Go to Appendix B (ASCII), Appendix C (Function Key) Complete End Save
51 5.3 Deletion Data You can delete character for up to 6 different barcode types. Steps 1. Scan the bar code for the desired set. 2. Scan the des
52Complete 3 Scan the numbers of characters need to be deleted Complete End Save > Delectation Set Number Set #1 Set #2 Set #3 Set #4 S
53UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 China Postage
54Code 2 of 6 Telepen Resvered5 LCD25 RSS-14 RSS Limited RSS Expanded All Codes None > Delete Start Position
55 Complete > Number of Characters to be deleted
56 Complete End Save
3 How to Configure 2.1 Flow Chart Start ConfigurationBar Codes ParametersRecall ParametersSet All DefaultsEndConfigurationAbout ConfigurationSavePar
57Appendix A-Decimal Value A
58B-ASCII Table NULL ETX ACK HT FF SI DC2 NAK CAN ESC GS RS STX
59ENQ BS VT SO DC1 DC4 ETB SUB SYN SOH EOT BEL LF CR
60DLE DC3 % $ & ( ' ) + * , comma . period - minus /
61; : < Less than > Greater than = ? @ EM FS US SPACE ″ ! #
620 Number Zero 1 Number One 2 3 4 5 6 7 8 9 A B C D
63E F G H I Letter I J K L M N O Letter O P Q R
64S T U V W X Y Z a b c d e f
65g h i j k l m n o p q r s t
66u v w x y z ~ } DEL { [ \ _ Underscore ]
42.3 Start Over Abort configuration Scan Abort configuration when you want to terminate current programming status. 2.4 Recall Replace the cu
67^ ` C-Function Key Table F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11
68F12 lnsert Delete Home End Page UP Page Down Left Up Right Down
Save Recall Set all default Start End Abort Version Information Ver 1.0
5 Operation 3.1 Beeper Option <High> Medium Low Off 3.2 Output Characters This function is related to the software of the host. The out
6Enable CR Suffix – The scanner transmits a carriage return after each scan. The cursor moves to the left once data are displayed. Enable LF Suffix